DMXPathfinder MR
Installer’s Guide
Version 1.2
February 2004.
480C - 36 Avenue S.E.
Calgary, AB, T2G 1W4
Canada
Phone: (403) 243-8110
Fax: (403) 287-1281
Web site: www.pathwayconnect.com
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - Installer’s Guide

DMXPathfinder MR Installer’s Guide Version 1.2 February 2004. 480C - 36 Avenue S.E. Calgary, AB, T2G 1W4 Canada Phone: (403) 243-811

Page 2 - CONTENTS

DMXPathfinder LR Installation & Assembly 9 Pin 1 -- Signal Common (shield) Pin 2 – DMX Data (-) Pin 3 – DMX Data (+) Pin 4 – Talkback Data (-) Pi

Page 3 - INTRODUCTION

DMXPathfinder LR Installation & Assembly 10 Patching To assign outputs to inputs, first remove the front cover to access the Crosspoint Card (

Page 4 - BEFORE STARTING

DMXPathfinder LR Index 11 Chapter 2: Maintenance & Testing TESTING THE INSTALLATION Once all connections are made and inspected for possible erro

Page 5 - DMXPathfinder

DMXPathfinder LR Index 12 To replace an Output Module card, first remove the four front-panel Phillips screws and the cover panel, then grasp the car

Page 6 - MOUNTING TERMINATION BOARDS

DMXPathfinder LR Index 13 The Fluke 650's signalling is not compatible with the DMXPathfinder MR electronics or any other DMX generating or rece

Page 7 - I/O CABLE INSTALLATION

DMXPathfinder LR Index 14 and transmitter circuits. Next, a DMX tester should be used to either transmit DMX in place of the control console, or rece

Page 8 - MODULE INSTALLATION

DMXPathfinder LR Index 15 INDEX A Advanced Troubleshooting · 13 Ambient temperature · 3 Assembly · 3 B bus terminator · 7 C CABLE A IN · 7 CABLE A(

Page 9 - I/O CABLE CONNECTION

DMXPathfinder MR Contents 1 CONTENTS INTRODUCTION...

Page 10

DMXPathfinder LR Introduction 2 INTRODUCTION WELCOME TO THE WORLD OF DMXPATHFINDER! This Installation Guide is intended to walk you through a typical

Page 11 - Patching

DMXPathfinder LR Installation & Assembly 3 Chapter 1: Installation and Assembly SUMMARY This section describes how to correctly assemble the DMX

Page 12 - MODULE CONFI GURATI ON

DMXPathfinder LR Installation & Assembly 4 Power Requirements -- A single-phase power source (50 or 60Hz, 100-240VAC, at 0.2A per Input Module

Page 13 - TEST PROCEDURES

DMXPathfinder LR Installation & Assembly 5 RACK SIZING AND PLACEMENT The system installer normally supplies the DMXPathfinder MR equipment rac

Page 14 - ADVANCED TROUBLESHOOTING

DMXPathfinder LR Installation & Assembly 6 One of two types of cable termination boards are normally supplied with the system to provide the phys

Page 15 - DMXPathfinder LR Index

DMXPathfinder LR Installation & Assembly 7 MODULE PREPARATION Unpack all of the DMXPathfinder MR system modules and accessories and arrange on

Page 16

DMXPathfinder LR Installation & Assembly 8 I/O CABLE CONNECTION Strip back about 3 inches (8cm) of cable jacket and braid shield from each in